The Toshiba G9000 series UPS is available in capacities of 80, 100, 160, and 225 KVA

The G9000 comes with an industry-leading three-year onsite warranty. It is designed for stand-alone or parallel use in up to four-unit configurations without requiring the use of a special switchgear cabinet.

Toshiba G9000 three year warranty

The Toshiba G9000 Uninterruptible Power System (UPS) utilizes state-of-the-art design and construction to deliver industryleading efficiency, reliability, and flexibility to meet today’s critical power demands.

Using the new Toshiba IGBT technology in the rectifier/converter, DC/DC chopper, and the inverter sections of the UPS, the G9000's double-conversion topology provides an AC/DC/AC efficiency of 96.5% at loads from 50% to 100%. Even at 20% loading, the efficiency remains greater than 94%. This is 10% to 20% better than current industry systems, making the G9000 excellent for N+1 parallel systems where loads are typically 30-40%.

Tweet

CAPS Customers

Toshiba G9000 - Additional Information

  • Features
  • Specifications
  • Service
  • Downloads

The Toshiba G9000 Uninterruptible Power System (UPS) utilizes state-of-the-art design and construction to deliver industryleading efficiency, reliability, and flexibility to meet today’s critical power demands.

Toshiba g9000 UPS Fast-switching IGBT control technology delivers up to 97% efficiency.
  • Full IGBT rectifier and harmonic input filter reduce input total harmonic distortion (THD) which also reduces heat loss in associated feed equipment and increases component life.
  • IGBT DC-DC chopper produces lower DC ripple on the charging circuit, extending battery and capacitor life.
  • Hybrid static bypass switch offers efficiency and dependability.
  • Improved output voltage regulation provides superior transient response, easily handling 100% step loads without requiring battery support.
  • Generator friendly interface allows sizing a 1.1 KW generator capacity to a 1.0 UPS KVA load.
  • The G9000 has the ability to combine up to eight modules for increased capacity/redundancy.
  • Each module is self-contained with its own switching & control intelligence. This control redundancy increases system reliability.
  • Toshiba’s G9000 is robustly engineered with highest quality components to ensure reliability.

High Efficiency Design Ensures Low Power Loss Even at Minimal Loads

An efficiency greater than 92.5% at 20% loading means lower power losses, reduced air conditioning needs, and reduced utility costs across a wide load range without sacrificing frequency or output voltage stability.

Smallest Footprint/Highest Power Density

Toshiba G9000 efficiency Graph

The G9000’s transformerless design makes it far lighter than conventional UPSs, and gives it a much smaller footprint compared to similar sized UPSs. With its compact size, the G9000 has the highest energy density per square foot of any UPS of similar capacity.

Model Number
T90S3S08KS6XSN
T90S3S10KS6XSN
T90S3S16KS6XSN
T90S3S22KS6XSN
Capacity
KVA/KW
80/72
100/90
160/144
225/202.5
Topology
True On-Line, Double Conversion, Advanced Multi-Level IGBT Technology
Input Voltage
480 V, Three-Phase, Three-Wire + Ground/Bypass Input, 480 V, Three-Phase, Three-Wire + Ground
Voltage Range
480 V, -20% to +15% (384 to 552 V Without Utilizing Battery)
Power Factor
Greater than 0.99
Current THD
<3% at 100% Load (No Input Filter Required)
Frequency
60 Hz (± 10%)
Output Voltage
480 V, Three-Phase, Three-Wire + Ground
Frequency
60 Hz, ±0.01% (In Free-Running Mode)
Voltage Regulation
±1.0% (0.5% Typical)
Power Factor
0.9 Lagging
1.0 (Unity)
Power Factor Range
0.9 Lagging to 0.95 Leading
Voltage THD
<2% for Linear Load, <5% for Non-Linear Load
Overload (Inverter)
125% for 2 Minutes; 150% for 60 Seconds
Overload (Bypass)
1000% for One Cycle
500% for One Cycle
Battery DC Link
480 VDC
Environment Temperature Range
32° to 104°F (0° to 40°C)
Relative Humidity
5% to 95% Non-Condensing
Heat Rejection
10,771 BTUs/Hour
13,463 BTUs/Hour
17,821 BTUs/Hour
25,060 BTUs/Hour
Efficiency (Full-Load)
95.80%
95.80%
96.50%
96.50%
Efficiency (20% Load)
92.50%
92.50%
94.70%
94.90%
Altitude
7380 Feet Maximum Without Derating (2250 Meters)
Audible Noise
70 dBA at 1 Meter
Dimensions Dimensions (W x D x H)
27.6 x 32.8 x 80.6 in.(700 x 832 x 2047 mm)
35.4 x 32.8 x 80.6 in.(900 x 832 x 2047 mm)
Weight
855 lbs. (388 kg)
855 lbs. (388 kg)
1160 lbs. (526 kg)
1230 lbs. (558 kg)
Features
Digital Signal Processor (DSP) Control, Fully Digital IGBT Converter & Inverter, High Efficiency Over Wide Load Range,
Transformer-Less Design, N+1 and N+N (Up to Four in Parallel) Capability, Dual-Input Feed, Electronic Battery Isolation,
RS232 and Dry Contact Interface, Small Footprint, Lightweight Design
Standards
UL 1778, CUL, ISO9001, ISO14001, ANSI C62.41 (IEEE 587), FCC Class A, Article 47, Part 15.B
Warranty
Three Years Onsite (Optional Two Year Extended Warranty)

Factory Witness Testing

Toshiba has recently completed construction of a 1500 KW Witness Test Facility at its plant in Houston, Texas. Customers can now perform witness testing to validate their system’s performance specifications in all operating modes prior to taking delivery. Multi-module parallel configurations, including battery or flywheel backup, can be assembled and tested in all modes before shipment for final installation.

Service Providers

Toshiba’s growing network of more than 80 Authorized Service Providers supply factory trained technicians to service and support Toshiba UPSs throughout the contiguous United States, Canada, Caribbean, Mexico, Central and South America.

Maintenance Agreements

Three standard levels of maintenance agreement packages are available to provide the service support appropriate to your needs and budget while maximizing the performance and service life of your Toshiba UPS. Tailored, sitespecific service agreements range from simple scheduled preventive maintenance programs to extended warranty programs with guaranteed response times, 24/7/365 coverage, and discounted replacement parts.

Preventive Maintenance

Derived Mean Time Between Failure (MTBF) rates are based on an ideal operating environment. Real operating environments vary from benign to outright hostile. Preventive maintenance will help ensure you get the maximum service out of your Toshiba system. The maintenance needs of a UPS are minimal but crucial.
  • Periodic inspection, calibration and adjustment of the UPS’s control and monitoring systems are necessary to ensure continued optimal performance and the highest level of reliability
  • Regular maintenance can help detect early signs of degradation in capacitors, fans, and other components, to allow for timely repair without the UPS unexpectedly failing. This is particularly important in harsh environments with excessive humidity, temperature extremes, frequent out-of-specification voltage excursions, and abrasive air particles.
  • Warranty

    The G9000 UPS and the UPS backup battery system are supported by Toshiba’s industry-leading three-year parts and labor warranty* and a 24/7/365 hotline. This ensures that customers get the quickest possible resolution to any warranty or service issues that may arise.

    * Conditional to system startup by an Authorized Toshiba UPS Service Provider. See three-phase warranty for details.

    G9000 Series Installation and Operation Manual
    G9000 Series Brochure.pdf
    Toshiba UPS Three Phase Warranty
    97 percent efficiency

    Want More Information?

    If you would like more information about the Toshiba G9000 or any other UPS, just fill out the form, and one of our Power Specialists will get back to you promptly.

    Please complete all required fields!

    First Name (*)
    Invalid Input
    Last Name (*)
    Invalid Input
    Email (*)
    Invalid Input
    Phone
    Invalid Input

    CALL: 800-800-4UPS (4788)

    Help Center

    • Frequently Asked Questions
    • Video Guides & documents
    • Contact CAPS
    • CAPS Privacy Policy

    Contact Info

    Computer/Air Power Systems
    2372 Walsh Ave,
    Santa Clara, CA 95051
    Telephone: (408) 855-1100
    Toll Free: (800) 800-4UPS (4877)

    CAPS Info

    Copyright 2011 Computer/Air Power Systems, Inc. (CAPS)

    Designed by Sturm Media & Communications